No. 3.—Return of Notices given to repair Boilers, etc. — continued.

umber. Type. Description of Itepairs. 3 2 1 1 1 1 6 2 1 9 1 1 Multitubular ,5 >; ,, >, ,, ,, )) New studs fitted to mudhole-doors. Patch fitted on bottom of shell. Patch fitted on bottom of shell, and several new tubes. Patch fitted on bottom of shell over cracked rivet-holes and grooving. Patch fitted on bottom of shell over wasted landings. Patch riveted over circumferential seams where cracked. Patches riveted over wasted portions of bottom. Patches taken off bottom of shell, and extended ones fitted. Patches under mountings renewed. Retubed. Retubed, and compensating-rings fitted to mudhole-openings. Retubed, compensating-ring fitted to mudhole-opening, and two new longitudinal stays in steam-space. Retubed, patch fitted on shell under check-valve, and new spigot to manhole-door. Several rivets renewed in shell. Several rivets renewed in steam-dome. Several tubes renewed. Sixteen new tubes fitted. Sixteen tubes drawn to clean boiler, and tubes afterwards renewed. Ten rivets renewed in steam-dome and sixteen in shell. Top row of tubes renewed. A number of new screwed stays fitted in sides of firebox. All new screwed stays fitted in firebox. Compensating-ring fitted to manhole-opening. Compensating-rings fitted to mudhole-openings. Compensating-rings fitted to mudhole-openings, and new dogs for mud-doors. Compensating-rings fitted to mudhole-openings, and several new tubes fitted. Corners of firebox repaired. Eight new screwed stays fitted in firebox. Eighteen new screwed stays fitted in firebox. Eleven new screwed stays fitted in firebox. Eleven new tubes fitted. Fifteen new screwed stays fitted in firebox. FiLteen new screwed s'ays fitted in firebox, and compensating-ring to mudhole-opening. Forty-eight new screwed stays fitted in firebox. Foundation-rings repaired. Fourteen new screwed stays fitted in firebox. Girders and stays renewed on firebox-crown, and compensatingrings fitted to mudhole-openings. Girder-stays renewed. New firebox and several patches on outer shell fitted. New girders fitted on crown of firebox. New girders fitted on crown of firebox, and several new stays fitted. New manhole-door fitted. New mudhole-doors fitted. New mudhole-doors fitted and openings dressed out. Nine new tubes fitted. Nine een new tubes fitted. One new cross-girder wi h three stays fitted to crown of firebox. One new longitudinal stay fitted. Patch fitted on firebox-crown, and four new screwed stays. Patch fitted on firebox-crown, and six new rivets put in front tubeplate. Patch fitted on side of firebox, and six new screwed stays. Patches on crown of firebox renewed. Patches on foundation-ring renewed, nine new tubes and one new mud-door fitted. Patch put on shell under feed-pump, and mudhole-opening compensated. Retubed. Retubed, and new tube-plate fitted. Retubed, and twent) r new screwed stays fitted in fLebox. Retubed, mudhole-opening compensated, and new mud-door. 1 ,, 1 1 5 1 1 1 1 2 1 1 22 1 ,, >5 >5 yy ,, Portable ,, >7 1 it 1 1 1 1 1 1 1 55 55 55 55 55 55 5) 1 1 1 1 55 55 55 55 1 1 1 1 1 6 2 1 1 1 1 1 1 55 J) 5, ,5 ,) j 5, 55 1 2 1 ,5 55 55 1 55 6 1 1 1 5? )) II ,,

Log in or create a Papers Past website account

Use your Papers Past website account to correct newspaper text.

By creating and using this account you agree to our terms of use.

Log in with RealMe®

If you’ve used a RealMe login somewhere else, you can use it here too. If you don’t already have a username and password, just click Log in and you can choose to create one.


Log in again to continue your work

Your session has expired.

Log in again with RealMe®


Alert